{"id":621,"date":"2024-02-02T14:26:24","date_gmt":"2024-02-02T14:26:24","guid":{"rendered":"https:\/\/sites.exeter.ac.uk\/oao\/?page_id=621"},"modified":"2024-02-02T14:59:21","modified_gmt":"2024-02-02T14:59:21","slug":"cape-verde-technical-details","status":"publish","type":"page","link":"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/","title":{"rendered":"Cape Verde &#8211; Technical Details"},"content":{"rendered":"\n<p>An Off-Axis Integrated-Cavity Output Spectroscopy (OA- ICOS) green-house gas analysers (GGA) is utilised to measure CO2 and CH4 concentrations in the atmosphere; and a second OA-ICOS analyser (N2O) continuously measures N2O and CO. These analysers regulate their internal cell temperature to reduce temperature fluctuations. Preconditioning of the atmospheric samples prior to measurement is performed by dropping the sample\u2019s temperature below the dew point to condense out the water. A coarse drier placed in line with a cryogenic trap combine to form an effective and chemical free drying technique. The trap is filled with glass beads to maximise the surface area the source air has to travel, hastening the extraction process.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"517\" src=\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0351-1024x768.jpg\" alt=\"\" class=\"wp-image-517\" srcset=\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0351-1024x768.jpg 1024w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0351-300x225.jpg 300w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0351-768x576.jpg 768w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0351-1536x1152.jpg 1536w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0351-2048x1536.jpg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"519\" src=\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0353-1024x768.jpg\" alt=\"\" class=\"wp-image-519\" srcset=\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0353-1024x768.jpg 1024w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0353-300x225.jpg 300w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0353-768x576.jpg 768w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0353-1536x1152.jpg 1536w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0353-2048x1536.jpg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"511\" src=\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0347-1024x768.jpg\" alt=\"\" class=\"wp-image-511\" srcset=\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0347-1024x768.jpg 1024w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0347-300x225.jpg 300w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0347-768x576.jpg 768w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0347-1536x1152.jpg 1536w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0347-2048x1536.jpg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/figure>\n\n\n\n<p>Each analyser has the capability to detect and factor water vapour concentration at precisions of 150 ppm and 50 ppm ( GGA and N2O respectively) at a frequency of 1Hz. However, drying of the source air prior to observation removes this requirement. Consequently, any internally computed dry values are discarded prior to our analysis.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-2 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" data-id=\"485\" src=\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0312-768x1024.jpg\" alt=\"\" class=\"wp-image-485\" srcset=\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0312-768x1024.jpg 768w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0312-225x300.jpg 225w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0312-1152x1536.jpg 1152w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0312-1536x2048.jpg 1536w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0312-scaled.jpg 1920w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"469\" src=\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0270-1024x768.jpg\" alt=\"\" class=\"wp-image-469\" srcset=\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0270-1024x768.jpg 1024w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0270-300x225.jpg 300w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0270-768x576.jpg 768w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0270-1536x1152.jpg 1536w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0270-2048x1536.jpg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"471\" src=\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0276-1024x768.jpg\" alt=\"\" class=\"wp-image-471\" srcset=\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0276-1024x768.jpg 1024w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0276-300x225.jpg 300w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0276-768x576.jpg 768w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0276-1536x1152.jpg 1536w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0276-2048x1536.jpg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/figure>\n\n\n\n<p>Imperfections, such as the previously mentioned temperature variation, ambient air and cell pressure fluctuations and water concentration inclusions are removed by the utilisation of a working tank in the system. The constant reference derived from the tank forms an essential part of the infrastructure delimiting both observational and calibration-based samples; thus, allowing for post-measurement drift compensation. To accomplish this, a linear interpolation, formed from taking the mean of the relevant working tank measurement, is computed between each of the delimiting working tanks and subtracted from the sample dataset to produce a baseline.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-3 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"657\" src=\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/02\/IMG_1952-1024x768.jpeg\" alt=\"\" class=\"wp-image-657\" srcset=\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/02\/IMG_1952-1024x768.jpeg 1024w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/02\/IMG_1952-300x225.jpeg 300w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/02\/IMG_1952-768x576.jpeg 768w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/02\/IMG_1952-1536x1152.jpeg 1536w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/02\/IMG_1952-2048x1536.jpeg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"653\" src=\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/02\/IMG_1950-1024x768.jpeg\" alt=\"\" class=\"wp-image-653\" srcset=\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/02\/IMG_1950-1024x768.jpeg 1024w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/02\/IMG_1950-300x225.jpeg 300w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/02\/IMG_1950-768x576.jpeg 768w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/02\/IMG_1950-1536x1152.jpeg 1536w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/02\/IMG_1950-2048x1536.jpeg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" data-id=\"651\" src=\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/02\/IMG_1949-768x1024.jpeg\" alt=\"\" class=\"wp-image-651\" srcset=\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/02\/IMG_1949-768x1024.jpeg 768w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/02\/IMG_1949-225x300.jpeg 225w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/02\/IMG_1949-1152x1536.jpeg 1152w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/02\/IMG_1949-1536x2048.jpeg 1536w, https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/02\/IMG_1949-scaled.jpeg 1920w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/figure>\n\n\n\n<p>Furthermore, Allan deviation was employed to determine an efficient noise filter to remove inherent systematic errors. The optimal averaging period for the filter was deemed to be 120 seconds [Ref: Heimann]. During processing, the dataset is split into segments (jogs) sufficient to encapsulate this after first discarding the first 90 seconds of the jog in order to accommodate the transition time between the distinct sample types. Any segment that does not meet the required length is subsequently discarded during plausibility testing. Removal of outliers, discarding the trimmed mean component \u00b1 5% and range bounding the data using standard deviation completes the data preparation phase.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>An Off-Axis Integrated-Cavity Output Spectroscopy (OA- ICOS) green-house gas analysers (GGA) is utilised to measure CO2 and CH4 concentrations in the atmosphere; and a second OA-ICOS analyser (N2O) continuously measures N2O and CO. These analysers regulate their internal cell temperature to reduce temperature fluctuations. Preconditioning of the atmospheric samples prior to measurement is performed by [&hellip;]<\/p>\n","protected":false},"author":715,"featured_media":533,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-sidebar-boxed-feature-img.php","meta":{"_acf_changed":false,"footnotes":""},"categories":[],"tags":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v23.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Cape Verde - Technical Details - ATMOSPHERIC OBSERVATIONS<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Cape Verde - Technical Details - ATMOSPHERIC OBSERVATIONS\" \/>\n<meta property=\"og:description\" content=\"An Off-Axis Integrated-Cavity Output Spectroscopy (OA- ICOS) green-house gas analysers (GGA) is utilised to measure CO2 and CH4 concentrations in the atmosphere; and a second OA-ICOS analyser (N2O) continuously measures N2O and CO. These analysers regulate their internal cell temperature to reduce temperature fluctuations. Preconditioning of the atmospheric samples prior to measurement is performed by [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/\" \/>\n<meta property=\"og:site_name\" content=\"ATMOSPHERIC OBSERVATIONS\" \/>\n<meta property=\"article:modified_time\" content=\"2024-02-02T14:59:21+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0363-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1920\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/\",\"url\":\"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/\",\"name\":\"Cape Verde - Technical Details - ATMOSPHERIC OBSERVATIONS\",\"isPartOf\":{\"@id\":\"https:\/\/sites.exeter.ac.uk\/oao\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0363-scaled.jpg\",\"datePublished\":\"2024-02-02T14:26:24+00:00\",\"dateModified\":\"2024-02-02T14:59:21+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/#primaryimage\",\"url\":\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0363-scaled.jpg\",\"contentUrl\":\"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0363-scaled.jpg\",\"width\":2560,\"height\":1920},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/sites.exeter.ac.uk\/oao\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Cape Verde &#8211; Technical Details\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/sites.exeter.ac.uk\/oao\/#website\",\"url\":\"https:\/\/sites.exeter.ac.uk\/oao\/\",\"name\":\"ATMOSPHERIC OBSERVATIONS\",\"description\":\"Remote monitoring stations in Norway and Cape Verde\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/sites.exeter.ac.uk\/oao\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Cape Verde - Technical Details - ATMOSPHERIC OBSERVATIONS","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/","og_locale":"en_US","og_type":"article","og_title":"Cape Verde - Technical Details - ATMOSPHERIC OBSERVATIONS","og_description":"An Off-Axis Integrated-Cavity Output Spectroscopy (OA- ICOS) green-house gas analysers (GGA) is utilised to measure CO2 and CH4 concentrations in the atmosphere; and a second OA-ICOS analyser (N2O) continuously measures N2O and CO. These analysers regulate their internal cell temperature to reduce temperature fluctuations. Preconditioning of the atmospheric samples prior to measurement is performed by [&hellip;]","og_url":"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/","og_site_name":"ATMOSPHERIC OBSERVATIONS","article_modified_time":"2024-02-02T14:59:21+00:00","og_image":[{"width":2560,"height":1920,"url":"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0363-scaled.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/","url":"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/","name":"Cape Verde - Technical Details - ATMOSPHERIC OBSERVATIONS","isPartOf":{"@id":"https:\/\/sites.exeter.ac.uk\/oao\/#website"},"primaryImageOfPage":{"@id":"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/#primaryimage"},"image":{"@id":"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/#primaryimage"},"thumbnailUrl":"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0363-scaled.jpg","datePublished":"2024-02-02T14:26:24+00:00","dateModified":"2024-02-02T14:59:21+00:00","breadcrumb":{"@id":"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/#primaryimage","url":"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0363-scaled.jpg","contentUrl":"https:\/\/sites.exeter.ac.uk\/oao\/wp-content\/uploads\/sites\/185\/2024\/01\/IMG_0363-scaled.jpg","width":2560,"height":1920},{"@type":"BreadcrumbList","@id":"https:\/\/sites.exeter.ac.uk\/oao\/cape-verde-technical-details\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/sites.exeter.ac.uk\/oao\/"},{"@type":"ListItem","position":2,"name":"Cape Verde &#8211; Technical Details"}]},{"@type":"WebSite","@id":"https:\/\/sites.exeter.ac.uk\/oao\/#website","url":"https:\/\/sites.exeter.ac.uk\/oao\/","name":"ATMOSPHERIC OBSERVATIONS","description":"Remote monitoring stations in Norway and Cape Verde","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/sites.exeter.ac.uk\/oao\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/sites.exeter.ac.uk\/oao\/wp-json\/wp\/v2\/pages\/621"}],"collection":[{"href":"https:\/\/sites.exeter.ac.uk\/oao\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/sites.exeter.ac.uk\/oao\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/sites.exeter.ac.uk\/oao\/wp-json\/wp\/v2\/users\/715"}],"replies":[{"embeddable":true,"href":"https:\/\/sites.exeter.ac.uk\/oao\/wp-json\/wp\/v2\/comments?post=621"}],"version-history":[{"count":3,"href":"https:\/\/sites.exeter.ac.uk\/oao\/wp-json\/wp\/v2\/pages\/621\/revisions"}],"predecessor-version":[{"id":661,"href":"https:\/\/sites.exeter.ac.uk\/oao\/wp-json\/wp\/v2\/pages\/621\/revisions\/661"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sites.exeter.ac.uk\/oao\/wp-json\/wp\/v2\/media\/533"}],"wp:attachment":[{"href":"https:\/\/sites.exeter.ac.uk\/oao\/wp-json\/wp\/v2\/media?parent=621"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sites.exeter.ac.uk\/oao\/wp-json\/wp\/v2\/categories?post=621"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sites.exeter.ac.uk\/oao\/wp-json\/wp\/v2\/tags?post=621"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}